The procedure to follow is described below:
1-Click Next, to the lower right, to continue;
2 -When the DOS window appears, disconnect the USB cable; wait approx. 10 seconds; reconnect
the USB cable (identied with the red ring ) to the PC. This action makes it possible to turn the Wa
Sensor board o and back on.
Figure 93
3- Press Ctrl+C to proceed with the sw update.
At this point, a window appears that displays the sw update progress. Wait for the update to nish.
Figure 94
If the update was successful, the message appears: “Software successfully loaded: disconnect and
reconnect the USB plug (of the GC cable) again. Now install the calibration database if necessary”.
New Group Cycle (D92):
Technical Service Guide - Rev. 5.1
Document uncontrolled when printed
Page 121