CASE 2: Only the following two commands are active if the database does not contain the data for
this specic equipment:
WRITE SERIAL NUMBER;
DOWNLOADCALIBRATIONFILES:DownloadthecalibrationlesforthewrienSN.An in-
ternet connection is required. The information remains stored in the database.
The commands are described in detail below.
10.3.1 PROGRAM WATT SENSOR BOARD
This makes it possible to perform the commands WRITE SERIAL NUMBER and WRITE TORQUE
TABLE in sequence in the Wa Sensor board. For details, see “10.3.2 Write serial number” and
“10.3.3 write torque table”.
IncaseoftheWaSensorIDboard,afterlaunchingthiscommand,brakecalibrationMUSTbeper-
formed.
10.3.2 WRITE SERIAL NUMBER
This command is used to write the Serial Number in the SW of the Wa Sensor board.
Ifthecommanddoesnotfunction:disconnecttheUSBcable(identiedwiththeredring)fromthe
PC;waitapprox.10seconds;reconnecttheUSBcable(identiedwiththeredring)tothePC.
If the Serial Number is entered correctly, a message appears indicating that the Serial Number was
entered correctly. Otherwise, a Serial Number insertion error message appears: enter the correct
Serial Number.
10.3.3 WRITE TORQUE TABLE
This command is used to automatically write the torque table in the Wa Sensor board.
At this point, the window displaying the progress of the torque table writing appears. Wait for the
loading to nish.
IncaseoftheWaSensorIDboard,afterlaunchingthiscommand,brakecalibrationMUSTbeper-
formed.
New Group Cycle (D92):
Technical Service Guide - Rev. 5.1
Document uncontrolled when printed
Page 126