6.7 PROCEDURE TO FOLLOW IF IT IS NECESSARY
TO REMOVE THE PLATE ON WHICH THE WATT
SENSOR ID IS FIXED
If it is necessary to remove the plate on which the Wa Sensor ID is xed (e.g.: ywheel removal),
the following procedure must be followed:
1. Before removing the plate, the reference distance between the plastic cover of the Wa Sen-
sor ID board and the ywheel must be measured.
NOTE: Starting from SN D92CBNE017001637, an assembly template was used in production that
adjusts the distance between the plastic cover of the Wa Sensor ID board and the ywheel to 18
mm.
Figure 47
2. Remove the two plate fastening and regulation screws (1) and (2). The plate can now be
removed.
New Group Cycle (D92):
Technical Service Guide - Rev. 5.1
Document uncontrolled when printed
Page 70