6.9 EQUIPMENT TESTING AFTER THE
INTERVENTION OF TECHNICAL SERVICE
After a technical service intervention, the technician MUST check - in the same conditions in which
the customer discovered the problem - that the fault has been resolved.
The technician MUST also perform the following standard operating tests:
- GROUP CYCLE CONNECT: pedal for a few seconds at a speed of at least 40 rpm to turn on
the display. After checking that the wi- connection is active, try to login using a TG device
(TGS key and MyWellness App (using Bluetooth)). The symbol on the display indicates that
the login was successful.
NOTE:Oldwi-console:itispossibletologinusingtheMywellnessAPP,viaBluetooth,withiOS
devicesbutnotwithAndroiddevices.Newwi-/ANT+console:itispossibletoloinusingtheMy-
wellness APP, via Bluetooth, with iOS and Android devices.
- GROUP CYCLE CONNECT: Perform a workout session for 20 seconds: pedal for a few
seconds at a speed of at least 40 rpm to turn on the display. Press the play buon to start the exer-
cise. Check that the display shows the warm up data. Turn the brake knob and check that the eort
levels shown on the display change as a result. Check that the machine resistance changes based
on the direction of knob rotation.
- GROUP CYCLE (RIDE): Perform a workout session for 20 seconds: turn the brake knob and
check that the machine resistance changes based on the direction of knob rotation.
- GROUP CYCLE CONNECT AND RIDE: Check that with high resistance, the belt does not
slip.
- GROUP CYCLE CONNECT AND RIDE: Check that there is a correct balance between the
play of the handlebar/seat and the rigidity of the vertical and horizontal sliding movement. Other-
wise, solve.
- GROUP CYCLE CONNECT AND RIDE: Visual inspection of the tightening of the pedal /
pedal crank.
Moreover:
- Check the presence / the state of wear of warning labels. Check if the warning labels are readable;
- Technogym doesn’t request to x the Group Cycle to the ground. However, the equipment can
be xed to the ground if requested by the customer for the specic location of installation. In this
case, check that the GC is actually xed securely.