<Handler>
When the transformer scan function is used, it is used to enter each setting screen of the
transformer scan. The function pages of this part are:
<Trans ID>
<Pin To Fixture>
<Pin Setup>
<Condition>
<Copy>
<Handler Mode>
<Stat>
<Tools>
2.4.3 [SYSTEM]
It is used to enter the system settings homepage. It is mainly about communication settings,
user management settings, Handlers settings. The function pages of this part are:
<System Info>
<Message>
<System check>
2.5 Basic Operation
The basic operation is as follows:
Use menu keys ([DISP], SETUP], [SYSTEM]) and soft keys to select the desired page.
Use the cursor keys ([←][→][↑][↓]), knob or directly touch the screen to move the cursor to
the area you want to set. When the cursor moves to a certain area, the area will be highlighted.
This area is the area where the cursor can be set.
The corresponding soft key function of the domain where the current cursor is located will be
displayed in the "soft key area". Select and press the desired soft key. Numeric keys, [←],
magnitude keys and [Enter] keys are used for data input. When a number key is pressed, you
can press the order key or the [Enter] key to end the data input.
2.6 Power on and off
Plug in 3-line power plug.
Caution: Keep the power-supply voltage and frequency conform to above specifications. Power
input phase line L, zero line N, ground line E should be the same as that of the instrument.
TH2840 series instruments use soft switches. After plugging in the three-wire power supply, some
indicators on the front panel will flash for a few seconds. After a few seconds, the power button will
light up in red, and other buttons with LED indications will go out.
Power on: Press the power switch at the lower left corner of the front panel to turn on the
instrument and display the startup screen. After the instrument is started, the power button lights up
green. The power button of TH2840 series instrument has memory function.