Trunks
318 DID Intercept Assignments
6-18 Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
11 DID/DNIS No. VMID Enter the VM mail box number which should answer calls for this DID/DNIS
number.
Possible values: Up to 10 digits (default = no value).
Note This code is only sent if using SMDI VM integration in Program 580,
01. This code will be replaced, after voice mail answers, by the DTMF
code set in Program 318, 15 DID/DNIS DTMF VMID code - if
programmed; therefore, if using Program 318, 15 code, this VMID
code is not necessary.
This mail box number will be sent to voice mail on a DID/DNIS call that rings
directly to voice mail; and, on a direct DID/DNIS call to a DN that forwards to
voice mail before it is answered by the DN.
If a DID/DNIS call is answered by a station and then transferred to a DN that
forwards to voice mail, this mail box number of the DID/DNIS number, or the
forwarding DNs mail box number will be sent to voice mail per Program 579,
01.
If this VMID code is not set, direct DID/DNIS calls will go to the VM general
greeting and DID/DNIS calls that forward from a DN to VM will go to the DNs
VMID mail box.
This Voice Mail box number is added to SMDI packets of direct and forwarded
DID\DNIS calls to voice mail as explained above.
12 DID/DNIS Name Enter DNIS Name. DNIS names can be assigned from the CTX WinAdmin (not
from programming phones).
Possible values: Up to 16 ASCII characters (default = no value)
15 DID/DNIS No. DTMF
VMID
Enter the VM mail box number which should answer calls for this DID/DNIS
number.
Possible values: Digits 0~9, * and #. For a pause enter Px, where x=0~9
(seconds), up to 10 characters (default = no value).
This mail box number will be sent to voice mail on a DID/DNIS call that rings
directly to voice mail; and, on a direct DID/DNIS call to a DN that forwards to
voice mail before it is answered by the DN.
If a DID/DNIS call is answered by a station and then transferred to a DN that
forwards to voice mail, the mail box number of the DID/DNIS number or the
forwarding DNs mail box number will be sent to voice mail per Program 579,
01.
If this VMID code is not set, direct DID/DNIS calls will go to the VM general
greeting and DID/DNIS calls that forward from a DN to VM will go to the DNs
VMID mail box.
This voice mail box number is sent to the VM port, as DTMF digits, after the VM
port answers a DID/DNIS call as explained above. These digits are sent to the
VM port if the CTX is set for SMDI or DTMF integration in Program 580, 01.