Telephone Button Programming
100 Series Programs
13-20 Strata CTX Programming - Part 3:Telephone Button Programming 04/03
105-18 Night Bell Relay
)%
, n,
+ROG
,
+ROG
n = 0~8
(default = 0)
Assign BIOU Relay (1~8) as the Night Relay - this relay activates
when the
system is in the Night Mode.
BIOU1 provides relays 1 to 4.
BIOU2 provides relays 5 to 8
Note The CTX100 ACTU built-in relay is programmed as relay 5.
For this relay operation, a virtual BIOU2 is installed, as
default, in a virtual equipment position - Cabinet 2 slot 5.
(Cab. 02 slot 05, PCB code 20, in program 100). To install an
actual BIOU2 and disable the ACTU built-in relay, use the
programming telephone. To remove the virtual BIOU2 and
then install the actual BIOU2 in Cab. 01/slot 01~08 in the
normal manner.
105-19 Display Preference
)%
, n,
+ROG
,
+ROG
n = 1. DNIS (default)
2. Caller ID
Whether to display DNIS or Caller ID.
105-20 Transit Counter
)%
, n,
+ROG
,
+ROG
n = 0~128
(default = 1)
The Networking Transit Counter limits the number of nodes through
which a QSIG call can pass before being terminated as a lost call.
105-21 Primary Clock
)%
, xxyyzz,
+ROG
,
+ROG
xx = Cabinet 1 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)
Enter data as xxyyzz.
zz=channel 01 if clock source is RPTU or RDTU
zz=channel 01, 02, 03 , or 04 if clock source is RBUU/RBUS or RBSU
Example: If the Primary Clock Source should be a assigned to an
RPTU in cabinet 5, slot 2, enter 050201.
Cabinet numbers:
• CTX100: Select 01 for Base and Expansion cabinet.
• CTX670: Select 01 for Base and 02~07 respectively for each
Expansion cabinet.
Slot numbers:
• CTX100: Select 01~04 for Base slots and 05~08 for Expansion
slots.
• CTX670: Select 01~08 for Base slots and 01~10 for Expansion
slots.
yy = Slot 01~8 (CTX100),
01~10 (CTX670)
zz = Circuit (01~30)
105-22 Secondary Clock
)%
, xxyyzz,
+ROG
,
+ROG
xx = Cabinet 1 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)
Enter data as xxyyzz:
zz=channel 01 if clock source is RPTU or RDTU
zz=circuit 01, 02, 03 , or 04 if clock source is RBUU/RBUS or RBSU
Example: If the Secondary Clock Source should be a assigned to an
RBUU in cabinet 5, slot 2, circuit 2; enter 050202.
Cabinet numbers:
• CTX100: Select 01 for Base and Expansion cabinet.
• CTX670: Select 01 for Base and 02~07 respectively for each
Expansion cabinet.
Slot numbers:
• CTX100: Select 01~04 for Base slots and 05~08 for Expansion
slots.
• CTX670: Select 01~08 for Base slots and 01~10 for Expansion
slots.
yy = Slot 01~8 (CTX100),
01~10 (CTX670)
zz = Circuit (01~30)
105-23 Call History Prefix 1
)%
, n,
+ROG
,
+ROG
n = 1. add (default)
2. not add
Whether prefix 1 is added or not in callback of Call History Feature.
105-24 Emergency Digits
Sent
)%
, n,
+ROG
,
+ROG
n = Up to 5 digits
(default = 911)
Default = “911” for North America. Enter alternative emergency
dialing strings up to 5 digits as required by local conditions.
105-25 DP Make Ratio
)%
, n,
+ROG
,
+ROG
n = 1. DPMakeRatio33
2. DPMakeRatio40
(default)
Dial pulse Make/Break ratio can be set to 33% or 40%. The default
value is 40%.
Programs 103~107 (continued)
Button Sequence Value(s) Summary