7 Troubleshooting intheField
When a design with a site-wide or design specific avoidance zone:
l Is unloaded.
one of the following full-screen warning messages appear:
l
A site-wide avoidance file is no longer being used. Press \ to continue.
or
l
A design specific avoidance file is no longer being used. Press \ to
continue.
Note These messages are displayed as warnings for the operator.
7.5.3 Other selected error messages
A system error has occurred. The application has been shut down for safety.
On start-up, one or more of the system’s software components failed to start.
Contact your site supervisor.
AS400
The AS400 has reported a fault. Faults may occur while the AS400 updates its
settings during, or immediately after, a firmware update or pitch calibration.
Try one of the following actions:
l Wait two minutes for the settings to take effect.
l Check all cable connections.
l To check that all devices are responding, use the procedure in 7.3 Running
system diagnostics.
If problems persist, contact your dealer.
172 GCS900 GradeControl System for Excavators Operator's Manual

Table of Contents

Other manuals for Trimble GCS900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trimble GCS900 and is the answer not in the manual?

Trimble GCS900 Specifications

General IconGeneral
System TypeGrade Control System
TechnologyGNSS, GPS, Laser
ConnectivityWireless
GNSS SupportGPS, GLONASS, Galileo, BeiDou
Power Supply12-24V DC
Operating Temperature-20°C to 55°C
IP RatingIP67
AccuracySub-inch to centimeter level
Storage Temperature-40°C to +70°C (-40°F to +158°F) (typical, component dependent)