7 Troubleshooting intheField
components are not responding.
Try one of the following actions:
l Check all cabling.
l To check that all the required components are responding, use the procedure in
7.3 Running system diagnostics.
If problems persist, contact your dealer.
Not enough memory to load the
The control box has run out of memory to load the design, design Avoidance Zone,
Site Map file, or Background Plan file. This may occur when using large:
l Designs
l Design Avoidance Zones
l Site Map files
l Background Plan files
As the Site Map and Background Plan files do not contain vertical guidance
information, you can continue working if they fail to load.
Failure to load the design Avoidance Zone will result in the design being unloaded.
Try one of the following actions:
l Shut down the control box and then restart it.
l Ask the design staff to reduce the size of the files.
Out of memory!
The control box has run out of memory. You may have turned on wireless
communications support when a large design or Background Plan file is loading.
Try one of the following actions:
l Shut down the control box and then restart it.
l Ask the design staff to reduce the size of the files.
Parameter Value Error
The value entered in the current field may exceed the recommended limits, or the
value is invalid. Check the value entered.
174 GCS900 GradeControl System for Excavators Operator's Manual