7.STATISTICAL AND ACCUMULATION FUNCTION SETTING AND OPERATION
106
Operation
1) Select setting mode 5.
2) One of input selections 1~4 is set to the Accumulation Clear. (1-Input Selection)
Accumulation clear through the RS-232C or RS-485 (option)
Immediate accumulation clearing is executed when the accumulation command “CJ” is received
from the host.
Accumulation clear through the CC-Link (option)
Accumulation clearing is executed by using the bit of RY0019 *.
Accumulation clearing is executed by ON edge.
* When occupied 4 or 2stations. When 1 station is occupied, RY0009 is used.
→→→
F
CNG/ENT CNG/ENT
5
SP2
→→
CNG/ENT CNG/ENT
1
UPPER
Input selection 1 (B2 pin)
Input selection 3 (B4 pin)
6 : Accumulation Clear
5 : Accumulation Command
4 : Stop
3 : Start
2 : Feed/Discharge
1 : Judge
0 : HOLD
Input selection 2 (B3 pin)
Input selection 4 (B5 pin)
6 : Accumulation Clear
5 : Accumulation Command
4 : Stop
3 : Start
2 : Feed/Discharge
1 : Judge
0 : HOLD
6 : Accumulation Clear
5 : Accumulation Command
4 : Stop
3 : Start
2 : Feed/Discharge
1 : Judge
0 : HOLD
6 : Accumulation Clear
5 : Accumulation Command
4 : Stop
3 : Start
2 : Feed/Discharge
1 : Judge
0 : HOLD
Host
F701-C
CJ
* No return data
CR