6.DISCHARGING CONTROL MODE
101
6-11. Weight Error / Sequence Error
Weight error
When the display is LOAD, OFL or ZALM, the output turns ON.
Sequence error
When the display is Err, the output turns ON.
Weight error and sequence error output signals are selectable by setting.
Operation
1) Select setting mode 5.
2) Set Output selection 1. (2-Output Selection)
→→→
F
CNG/ENT CNG/ENT
5
SP2
Output Selection 1 (B9 pin)
→→
ZERO
CNG/ENT CNG/ENT
2
LOWER
ZERO
2 : Weight error or sequence error
1 : Sequence error
0 : Weight error