6.DISCHARGING CONTROL MODE
100
6-10. Net Over / Gross Over
This function warns you that the Net or Gross weight exceeds the entered control value.
a) Net Over (Input range / 0 ~ 99999)
b) Gross Over (Input range / 0 ~ 99999)
a)
1) Select setting mode 3.
2) Input the Net Over. (4-Net Over)
b)
1) Select setting mode 3.
2) Input the Gross Over. (5-Gross Over)
Conditional formula Display
Net Over
Net weight > Net Over set value
Gross Over
Gross weight > Gross Over set value
→→→
F
CNG/ENT CNG/ENT
3
NEAR Z
.
→→ →
CNG/ENT CNG/ENT
Net Over
(0 ~ 99999)
4
SP1
→→→
F
CNG/ENT CNG/ENT
3
NEAR Z
.
→→ →
Gross Over
(0 ~ 99999)
CNG/ENT CNG/ENT
5
SP2