6.DISCHARGING CONTROL MODE
96
6-9. Judging Times / AZ Times / At Start Near Zero Confirmation /
At Start Weight Value Confirmation / Adjust Feeding /
Adjust Feeding Time
a) Judging Times
The Selection whether conduct the judgment on Over, Under or Go when complete signal is
displayed after completing the weighing.
Set the number from 00 to 99.
Example When the number of Judging Times is set to 2.
00 : Without judging
01 : Conducting judging every time
02 : Conducting an judging for every twice
03 : Conducting an judging for every three times
99 : Conducting an one judging in 99 times
Complete
Judging
AFFC.
Judging Times 2 times
Average count of AFFC. 2 times
The auto free fall compensation function stores compensation samples by
using the Over/Under judgment signals.
If the number of Judging Times is set to 00 (no judgment), the F701-C cannot
store such samples for auto free fall compensation, so that the compensation
function does not work.
For using the auto free fall compensation function, set the number of Judging
Times to 01 or more.
Request

Table of Contents

Other manuals for Unipulse F701-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unipulse F701-C and is the answer not in the manual?

Unipulse F701-C Specifications

General IconGeneral
BrandUnipulse
ModelF701-C
CategoryAccessories
LanguageEnglish

Related product manuals