4.CALIBRATION
47
4-4-4. Capacity
Register the maximum capacity of the scale. If the registered value exceeds by 9 scale divisions,
display shows over scale, “ ”. (Input range / 0 ~ 99999)
Operation
1) Select setting mode 3.
2) Input the Capacity. (2-Capacity)
4-4-5. Minimum Scale Division
Register the minimum unit (scale division) of the scale. (Input range / 1 ~ 100)
Operation
1) Select setting mode 3.
2) Input the Min. Scale Division. (3-Min. Scale Division)
→→→
F
CNG/ENT CNG/ENT
3
NEAR Z
.
→→
Capacity
(0 ~ 99999)
2
LOWER
CNG/ENT CNG/ENT
→→→
F
CNG/ENT CNG/ENT
3
NEAR Z
.
→→
Min. Scale Division
(1 ~ 100)
CNG/ENT CNG/ENT
3
NEAR Z
.