7-21
Alarm Configuration
• NotifyUponClear: When this item is enabled, the TSM/RSM will send additional
notification when the situation that caused the alarm has been corrected. For
example, when Notify Upon Clear is enabled for the Buffer Threshold Alarm, the
TSM/RSM will send initial notification when it detects that the amount of data stored
in the buffer for a given serial port has exceeded the user-defined Buffer Threshold
value, and then send a second notification when it determines that the amount of
data in the buffer has fallen below the Buffer Threshold value. (Default = On)
• EmailMessage: Enables/Disables email notification for this alarm. (Default = On)
• Address1,2,and3: These parameters are used to select which of the three email
addresses defined via the "Email Messages" menu (see Section 5.9.11) will receive
the email alarm notification messages generated by this alarm. The Address
parameters can be used to select one, or any combination of the addresses defined
via the Email Messages menu. (Default = All On)
Note:IfEmailaddresseshavebeenpreviouslyspecified,thenthetextunder
theparameterswilllistthecurrent,userdefinedemailaddresses.
• Subject: This parameter is used to define the text that will appear in the "Subject"
field for all email notification messages generated by this alarm. (Default = "Alarm:
Buffer Threshold")