5-2
Basic Configuration
To access command mode via the Text Interface, proceed as follows:
Notes:
• Whencommunicatingwiththeunitforthefirsttime,youwillnotbeableto
contacttheunitviaTelnetuntilyouhaveaccessedcommandmode,viaLocal
PCorSSHClient,andusedtheNetworkParametersMenutoenableTelnet
asdescribedinSection5.9.
• WhenconnectingyournetworkcabletoaTSM/RSMunitthatincludestwo
Ethernetports(e.g.,TSM-DPEseriesorRSM-8R8-DEseries)makecertainto
connecttoPortETH0.
1. Contact the TSM/RSM Unit:
a) ViaLocalPC: Start your communications program and press [Enter]. Wait
for the connect message, then proceed to Step 2.
b) ViaNetwork: The TSM/RSM includes a default IPv4 format IP address
(192.168.168.168) and a default IPv4 format subnet mask (255.255.255.0.)
This allows you to contact the unit from any network node on the same subnet,
without first assigning an IP Address to the unit. For more information, please
refer to Section 5.9.
i. ViaSSHClient: Start your SSH client, and enter the TSM/RSM’s IP
Address. Invoke the connect command, wait for the connect message,
then proceed to Step 2.
ii. ViaTelnet: Start your Telnet Client, and then Telnet to the TSM/RSM’s IP
Address. Wait for the connect message, then proceed to Step 2.
c) ViaModem: Use your communications program to dial the number for the
phone line that you have connected to the TSM/RSM's internal modem port.
2. Login/PasswordPrompt: A message will be displayed, which prompts you to
enter a username (login name) and password. The default username is "super" (all
lower case, no quotes), and the default password is also "super".
5.1.2. The Web Browser Interface
The Web Browser Interface consists of a series of web forms, which can be used to
select configuration parameters and perform reboot operations, by clicking on radio
buttons and/or entering text into designated fields.
Note:InordertousetheWebBrowserInterface,WebAccessmustfirstbe
enabledviatheTextInterfaceNetworkParametersMenu(/N),theTSM/RSM
mustbeconnectedtoaTCP/IPnetwork,andyourPCmustbeequippedwitha
JavaScriptenabledwebbrowser.
1. Start your JavaScript enabled Web Browser, key the TSM/RSM’s default IPv4 format
IP address (192.168.168.168) into the web browser’s address bar, and
press [Enter].
2. Username/PasswordPrompt: A message box will prompt you to enter your
username and password. The default username is "super" (all lower case, no
quotes), and the default password is also "super".