b) ThirdPartyConnection: Your resident port issues a /C command to create a
connection between two other ports.
i. To connect Port 3 to Port 4, type /C 3 4 [Enter].
ii. While Ports 3 and 4 are connected, your resident port will still recognize
commands. Type /S [Enter] to display the Status Screen. The "STATUS"
column should now list Ports 3 and 4 as connected and the other ports as
"Free".
iii. Issue a Third Party Disconnect command; type /D 3 [Enter]. The unit
will display the "Are you Sure (y/n)?" prompt. Type y and press [Enter] to
disconnect.
iv. Type /S [Enter] to display the Status Screen. The "STATUS" column
should now list Ports 3 and 4 as "Free".
Note:AlthoughtheWebBrowserInterfacecannotbeusedtoconnectTSM/
RSMserialports,itcanbeusedtodisconnectTSM/RSMserialportsas
describedinSection9.1.1.3.
3. ControllingOutlets(RSM-8R8SeriesModelsOnly): You may wish to perform
the following tests in order to make certain that the switched outlets are functioning
properly.
Notes:
• SwitchedoutletscanalsobecontrolledviatheWebBrowserInterfaceas
describedinSection9.2.
• TheSwitchedOutletsarenotpresentonTSMSeriesunitsorRSM
SeriesUnits.
a) RebootOutlet: At the command prompt, type /BOOT 1 and press [Enter].
The status indicator for Plug 1 should go Off, pause for a moment and then go
back On, indicating that the boot cycle has been successfully completed.
b) SwitchOutletOff: At the command prompt, type /OFF 1 and then press
[Enter]. The status indicator for Plug 1 should go Off, indicating that the
command has been successfully completed. Leave Plug 1 in the "Off" state,
and then proceed to the next step.
c) SwitchOutletOn: At the command prompt, type /ON 1 and press [Enter].
The status indicator for Plug 1 should then go back On, indicating that the
command has been successfully completed.
4. ExitCommandMode: To exit command mode, type /X and press [Enter].
This completes the Quick Start procedure for the TSM/RSM. Prior to placing the unit
into operation, it is recommended to refer to the remainder of this user’s guide for
important information regarding advanced configuration capabilities and more detailed
operation instructions. If you have further questions regarding the TSM/RSM unit,
please contact WTI Customer Support as described in Appendix D.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WTI TSM Series and is the answer not in the manual?

WTI TSM Series Specifications

General IconGeneral
BrandWTI
ModelTSM Series
CategoryRemote Control
LanguageEnglish

Related product manuals