5 SUPPLEMENT
5-14
3. G-code (Group02)
A. Plane selection
1. Command
Commands G17, G18 and G19 are used to select a plane for motion control.
Registering the three fundamental axes as parameters allows you to select a plane
generated by any two non-parallel axes.
4. G-code (Group03)
A. Absolute/incremental data input
1. Command
Setting of G90 or G91 allows succeeding dimensional data to be processed as absolute
data or incremental data. Setting of arc radius (with address R) or arc center position
(with addresses I, J, K) for circular interpolation, however, must always refer to
incremental data input, irrespective of preceding G90 command.
[in G90 mode]: Ending point (X-axis)
[in G91 mode]: Movement distance (X-axis)
±99999.9999 (mm)
±9999.99999 (in)
[in G90 mode]: Ending point (Y-axis)
[in G91 mode]: Movement distance (Y-axis)
±99999.9999 (mm)
±9999.99999 (in)
[in G90 mode]: Ending point (Z-axis)
[in G91 mode]: Movement distance (Z-axis)
±99999.9999 (mm)
±9999.99999 (in)
[in G90 mode]: Ending point (Additional -axis)
[in G91 mode]: Movement distance (Additional -axis)
±99999.9999 (mm)
±9999.99999 (in)
±9999.99999 (°)
Serial No. 294060
Copyright (c) 2013 YAMAZAKI MAZAK CORPORATION. All rights reserved.