11.1 List of Parameters
11.1.2 List of Parameters
11-16
PnBAC
2
/SEL5 (Program
Step Selection
Input 5) Signal
Allocation
0000h to
00C3h
00A0h
After
restart
Setup page 5-11
PnBAF
2
/S-ON (SERVO
ON) Signal Alloca-
tion
0000h to
00C3h
00B0h
After
restart
Setup page 5-12
Continued on next page.
Continued from previous page.
Parameter
No.
Size Name
Setting
Range
Setting
Unit
Default
Setting
When
Enabled
Classi-
fication
Reference
n.X Signal Usage Method
0
The /SEL5 (Program Step Selection Input) signal is active when the input signal is
ON (closed).
1
The /SEL5 (Program Step Selection Input) signal is active when the input signal is
OFF (open).
2 The /SEL5 (Program Step Selection Input) signal is always active.
3 The /SEL5 (Program Step Selection Input) signal is always inactive.
n.X
Signal Terminal Number
Same as PnBA0 = n.X.
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.X Signal Usage Method
0
The system changes to the SERVO ON state (power is supplied) and operation is
enabled when the input signal turns ON (closes).
1
The system changes to the SERVO ON state (power is supplied) and operation is
enabled when the input signal turns OFF (opens).
2 The system is always in the SERVO ON state.
3 The system is always in the SERVO OFF state.
n.X Signal Terminal Number
Same as PnBA0 = n.X.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)