4.9 Dimensional Drawings of Duct-ventilated SERVOPACK Model
4-31
4
4.9 Dimensional Drawings of Duct-ventilated SERVOPACK Model
4.9.1 Three-phase 200 V: 6.0 kW/7.5 kW (60ADA-P to 75ADA-P)
7.9
(0.31)*
L1 L2 L3 B1 B2+-
UV W
125 (4.92)
27
(1.06)
87.5
(3.44)
90 (3.54)
5.5
(0.22)*
5.5
(0.22)*
L1C
!WARNING
MODE/SET DATA/
Ver.
POWER
BATTERY
CHARGE
L2C
CN2
CN1
CN3
CN5
CN8
SGDM-
171 (6.73)
Max.230 (9.06)
41
(1.61)
123.5
(4.86)
65.6*
(2.58)
19
(0.75)
51
(2.01)
66 (2.60)
12.5 (0.49)
46
(1.81)
205 (8.07)
25 (0.98)
30.5 (1.20)
9
(0.35)
100.5
(3.96)
282.6 (11.13)
7 (0.28)
12.5 (0.49)
28.3 (1.11)*
Max.
350 (13.78)
7.5
(0.30)
335 (13.19)
7.5 (0.30)
12.5 (0.49)
Cooling fan
107 (4.21)
10 (0.39)
21
(0.83)
21.9 (0.86)*
312.2 (12.29)
15.9 (0.63)*
Max.235 (9.25)
205 (8.07)
219 (8.62)
7 (0.28)
7
(0.28)
82 (3.23)
34
(1.34)
316 (12.44)
335 (13.19)
7.5 (0.30)
2.5 (0.10)*
7.5 (0.30)*
11.5 (0.45)*
7.5 (0.30)*
2
×
φ6 (φ0.24)
holes
Punched hole
145 (5.71)
217.3 (8.56)*
4.8 (0.19)*
110 (4.33)
YASKAWA
SERVOPACK 200V
Control circuit
terminal
M4
Main circuit
terminal M6
M8
Ground terminal
Ground
terminal
Main
circuit
terminal
Control
circuit
terminal
A
View A
* Reference length
Units: mm (in)
Approx. mass: 14 kg (30.86 lb)
Mounting Hole Diagram
4×M6 taps
Name-
plate
External Terminal Connector
SERVOPACK Connector
Connector
Symbol
SERVOPACK
Connector Model
Manufacturer
CN1 10250-52A2JL Sumitomo 3M Co., Ltd.
CN2 53460-0611 Molex Japan Co., Ltd.
CN3 10214-52A2JL Sumitomo 3M Co., Ltd.
L1C L2CL2 L3L1
External
regenerative
resistor
B1 B2
200 VAC
50/60 Hz
Three-phase
200 VAC
50/60 Hz
Single-phase
Main circuit
power supply
Control power
supply
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com