EasyManuals Logo

YASKAWA SGDM Series User Manual

YASKAWA SGDM Series
615 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #560 background imageLoading...
Page #560 background image
11 Inspection, Maintenance, and Troubleshooting
11.2.3 SERVOPACK’s Parts Replacement Schedule
11-22
11.2.3 SERVOPACK’s Parts Replacement Schedule
The following electric or electronic parts are subject to mechanical wear or deterioration over time. To avoid
failure, replace these parts at the frequency indicated.
Refer to the standard replacement period in the following table, contact your Yaskawa representative. After
an examination of the part in question, we will determine whether the parts should be replaced or not.
The parameters of any SERVOPACKs overhauled by Yaskawa are reset to the factory settings before ship-
ping. Be sure to confirm that the parameters are properly set before starting operation.
Table 11.8 Periodical Part Replacement
Part Standard Replacement
Period
Operating Conditions
Cooling Fan
4 to 5 years
• Ambient Temperature: Annual average of 30°C
• Load Factor: 80% max.
• Operation Rate: 20 hours/day max.
Smoothing Capacitor
7 to 8 years
Relays
Fuses
10 years
Aluminum Electrolytic
Capacitor on Circuit Board
5 years
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA SGDM Series and is the answer not in the manual?

YASKAWA SGDM Series Specifications

General IconGeneral
BrandYASKAWA
ModelSGDM Series
CategoryServo Drives
LanguageEnglish

Related product manuals