7  Digital Operator/Panel Operator
7.4.1  List of Monitor Modes
7-30
(4) Monitor Display of Reference Pulse Counter and Feedback Pulse Counter
The monitor display of reference pulse counter and feedback pulse counter is expressed in 32-bit hexadecimal.
When the control power supply is turned ON, reference pulse and feedback pulse will be “0.”  The counter 
value increases by forward references, and decreases by reverse references.  
Displays the pulse number from 0 to 4294967295 in sequence.  If one pulse is decreased from 0, the digital 
operator and the panel operator display 4294967295 and then decrease from this pulse number.  Also, if one 
pulse in increased from 4294967295, the digital operator and the panel operator display 0 and increase from 
this pulse number.  
The feedback pulse will be 65536 pulse/rev, when using the 16-bit encoder.  The feedback pulse will be 
131071 pulse/rev, when using the 17-bit encoder.
Step
Display after 
Operation
Digital 
Operator
Panel 
Operator
Description
1
Press the DSPL/SET or MODE/SET Key to select 
the monitor mode.
2
Press the UP or DOWN Key to select “Un00C” or 
“Un00D.”
3
Press the DATA/ENTER Key once, or DATA/
SHIFT Key for more than one second to display the 
data of the selected monitor number.
4
Press the UP or DOWN Key to display the lower 
16-bit data.
5
Press both UP and DOWN Keys simultaneously 
while the display on the left appears to clear the 32-
bit counter data.
(The display shown on the left is of the lower 16-bit 
data.)
6
Press the DATA/ENTER Key once, or DATA/
SHIFT Key for more than one second to return to 
the display of monitor number.
DSPL
SET
(DSPL/SET Key)
MODE/SET
(MODE/SET Key)
The upper 16-bit data
DATA
ENTER
(DATA/ENTER Key
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
The lower 16-bit data
(Press simultaneouly)
Press simultaneously
+
DATA
ENTER
(DATA/ENTER Key
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com