Routine Maintenance
207
8.
Important • This part of the procedure should be performed only by experienced users and only
when the cutter blade is not fully exposed for cleaning, as shown in the previous step.
8-a. Remove the cutter mounting screw.
8-b. Slide the cutter module to the right to align the cutter assembly tabs (1) and cutter cover
tabs (2) with the corresponding slots (3) in the printer, and then lift the cutter module out of
the printer. Take care not to damage the wires that connect the cutter module to the printer.
If desired, you may disconnect these wires.
8-c. On the back of the cutter module, rotate the cutter motor thumbscrew to fully expose the
cutter blade.