Specifications
263
Communication Interface Specifications
The available communication interface connectors are shown in Figure 26. Your printer may not have all of
the connections shown here, and a ZebraNet wireless print server option may also be present on your
printer. You may send label formats to the printer through any communication interface that is available on
your printer.
Figure 26 • Location of Communication Interfaces
You must supply all data cables for your application. The use of cable strain relief clamps is recommended.
Ethernet cables do not require shielding, but all other data cables must be fully shielded and fitted with
metal or metalized connector shells. Unshielded data cables may increase radiated emissions above the
regulated limits.
To minimize electrical noise pickup in the cable:
• Keep data cables as short as possible.
• Do not bundle the data cables tightly with the power cords.
• Do not tie the data cables to power wire conduits.
Parallel port
Internal wired Ethernet print server
Serial port
USB port