Specifications
265
RS-232/C Serial Data Interface
• 2400 to 115000 baud
• parity, bits/character
• 7 or 8 data bit
• XON-XOFF, RTS/CTS, or DTR/DSR handshake protocol required
• 750mA at 5 V from pins 1 and 9
Limitations and Requirements
• You must use a null-modem cable to connect to the printer or a null-modem adapter if using a
standard modem cable.
• Maximum cable length of 50 ft (15.24 m).
• You may need to change printer parameters to match the host computer.
Connections and Configuration The baud rate, number of data and stop bits, the parity, and the
XON/XOFF or DTR control must match those of the host computer.
Optional Connections
Wireless print server
See Wireless Specifications on page 266 for more information.
Limitations and Requirements
• Can print to the printer from any computer on your Wireless Local Area Network (WLAN).
• Can communicate with the printer through the printer’s web pages.
• The printer must be configured to use your WLAN.
• Can be installed only in the top option slot.
Configuration Refer to the
ZebraNet Wired and Wireless Print Servers User Guide
for configuration
instructions. A copy of this manual is available at http://www.zebra.com/manuals.
IEEE 1284 Bidirectional Parallel Data Interface
Limitations and Requirements
• Maximum cable length of 10 ft (3 m).
• Recommended cable length of 6 ft (1.83 m).
• No printer parameter changes required to match the host computer.
• Can be installed in either the top or bottom option slot.
Connections and Configuration No additional configuration is necessary.
Applicator interface
with DB15F connector