Ascotel IntelliGate 2025/2045/2065
Part 2 Call Routing 325
Analogue-Analogue (A-A) or Digital-Analogue (D-A)
• Release on the analogue interface cannot be guaranteed with these connec-
tion types. On analogue network interfaces the PBX only recognises loop inter-
ruptions but not polarity reversals, busy tones, etc., as a release criterion.
Detection of the loop interruptions can be activated or deactivated throughout
the system.
• Any exchange-to-exchange connection is disconnected at the latest after 2
hours.
• The maximum duration of an analogue exchange-to-exchange connection can
be further restricted for the A-A connection type (1...120 minutes).
Note:
As release cannot be guaranteed for connection types D-A and A-A,
unintentional high costs can occur. What's more the national guidelines
and regulations should be observed before enabling these connection
types.
System configuration
Tab. 2.58: Exchange-to-exchange connections: System configuration
Parameter Parameter value Remarks
Exchange settings:
• Exchange-to-exchange
connection
Not allowed / Only digital-digital / Also
digital-analogue / Also analog-analog
Throughout the system
• Disconnect timeout <1...120 minutes> applies only to connection type
"Analogue-Analogue"
• Wait for connection Yes / No For description see page 442
Subscriber settings:
• Exchange-to-exchange
connection
Not allowed / Only digital-digital / Also
digital-analogue / Also analog-analog /
According to exchange settings
Priority over the setting for the sys-
tem as a whole
Abbreviated dialling set-
tings:
• Exchange-to-exchange
connection
Yes / No Priority over the exchange setting for
the system as a whole and the sub-
scriber-specific setting