Ascotel IntelliGate 2025/2045/2065
648 Planning DECT systems Part 3
Selection of multiple radio units to measure (display 2)
Fig. 3.46: Measure / Group state
Display of the voice quality (bar indicator = standard indicator)
Fig. 3.47: Measure and Re-Measure / Locked
65<––.––.––
1000101511
haz0349aaxxb0
• Field strength value of the first radio unit in the group
• This radio unit information is shown in the status line.
When the signal is too weak, a line is shown instead of the radio unit number
• Hexadecimal representation of the full RFPI
1438 0s17.65
Hon $$$$
haz0346aaxxc0
• RFPI: Radio Fixed Part Identity
• Field strength of the RU (dBµV)
• Quality bar indicator (CRC errors and field strength)
–
$$$$Very good
–
$$$Good
–
$$ Sufficient
–
$ Poor
–
. No signal
• Handover behaviour
– Hon = Enable handover by pressing the Foxkey
– Hoff = Bar handover by pressing the Foxkey
• Handover notification (dot)
(if handover is successful, new RFPI appears without a dot)
• Handset is synchronized to this radio unit