Ascotel IntelliGate 2025/2045/2065
Part 7 Operations supervision 931
Tab. 7.9: Operating state displays of the 7-segment display in normal mode
Note:
If the HEX rotary switch is in position B, the current software version will
be displayed instead of the port states.
Besides the normal mode there are also various other modes with their own status
display on the 7-segment display.
Tab. 7.10: Operating state displays other than normal mode (selection)
7-segment display Detailed Description State / Remarks
Point is flashing
1)
1)
Combinations of displays are possible
System in operation
Upper segment lit
1)
Internal port in operation
Middle segment lit
1)
External port in operation
Lower segment lit
1)
PBX prebarred
7-segment display Detailed Description State / Remarks
All segments lit Display test during startup
Rapidly descending segments RAM test during startup
1)
Permanently displayed Start of the startup mode
Permanently displayed Preparing to load the system soft-
ware or searching for system soft-
ware
Rotating segments, forming the figure
"8"
Loading the system software
Permanently displayed Action successfully completed