126 6 Programming
6.2 Folders
G-code Description Comment
G28
Return to Home Reference
MILLPWR
G2
does not have a method for establishing a “home”
position. If one or more coordinates are specified in the block, the table/
quill will rapid to that location. Program execution will continue with the
next program block.
G30
G40 Cancel Cutter Compensation MILLPWR
G2
supports automatic cutter compensation. Enable cutter
compensation using G41 (left) or G42 (right). Disable compensation
using G40 (center).
G41 Cutter Compensation (Left)
G42 Cutter Compensation (Right)
G43 Tool Length Offset (+) MILLPWR
G2
does not support tool length offsetting. The offset is
retrieved from MILLPWR
G2
’s tool library when a tool change is
executed. These commands are ignored.
G44 Tool Length Offset (-)
G49 Cancel Tool Length
G54
Work Coordinate System
MILLPWR
G2
does not support presettable work coordinate systems.
G54 through G59 are ignored.
G55
G56
G57
G58
G59

Table of Contents