Lesson 1 – Analog Modules
114
V Source in Source Unit or Measure Unit
Table 24 MCA V Source Key Specifications
Specification Value
Pin counts 4 (one at a time) per source unit or measure unit.
8 source or measure units in module
Voltage Force:
Range For Source Unit (SRCA):
±3.5 V @ ≥ 10 kohm load to GND
For Measure Unit (MESA):
±3 V @ ≥ 10 kohm load to GND
Resolution 0.1 mV
Accuracy ±0.1% of setting ±5mV @ ≥ 10 kohm load to GND
This accuracy is when the load impedance value is speci-
fied. With the specified value, the software applies the correc-
tion of the voltage across the output impedance (52 ohm
nominal). If the specified load impedance value differs from the
true value by x%, an additional error of x/(1 + Z/52) % occurs,
where Z is the true load impedance. For example, when Z = 10
kohm and x = ±1%, add ±0.0052% of setting.
Output current range ±3 mA