Configuring Ethernet OAM Configuring Ethernet OAM
page 8-10 OmniSwitch 6800/6850/9000 Network Configuration Guide March 2008
Configuring the Fault Alarm Time
The Fault Alarm time is the period of time during which one or more defects should be detected before the
Fault Alarm is issued. The ethoam fault-alarm-time command can be used to configure the timeout value
for the Fault Notification Generation Alarm Time.
To configure the Fault Alarm time, enter the ethoam fault-alarm-time command, followed by the number
of seconds.
For example, to configure the Fault Alarm time value as 10 seconds, you would enter:
-> ethoam fault-alarm-time 10 end-point 100 domain esd.alcatel-lucent.com asso-
ciation alcatel_sales
Configuring the Fault Reset Time
The Fault Reset time is the time interval in which Fault Alarm is re-enabled to process the faults. The
ethoam fault-reset-time command can be used to configure the timeout value for the Fault Notification
Generation Reset Time.
To configure the Fault Reset time, enter the ethoam fault-reset-time command, followed by the number
of seconds.
For example, to configure the Fault Reset time interval as 5 seconds, you would enter:
-> ethoam fault-reset-time 5 end-point 100 domain esd.alcatel-lucent.com associ-
ation alcatel_sales

Table of Contents

Other manuals for Alcatel-Lucent OmniSwitch 6800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniSwitch 6800 Series and is the answer not in the manual?

Alcatel-Lucent OmniSwitch 6800 Series Specifications

General IconGeneral
BrandAlcatel-Lucent
ModelOmniSwitch 6800 Series
CategorySwitch
LanguageEnglish

Related product manuals