EasyManua.ls Logo

Alcatel-Lucent OmniSwitch 6800 Series - Sflow Overview; Sflow Specifications; Sflow Defaults

Alcatel-Lucent OmniSwitch 6800 Series
926 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnosing Switch Problems sFlow Overview
OmniSwitch 6800/6850/9000 Network Configuration Guide March 2008 page 35-7
sFlow Overview
The following sections detail the specifications, defaults, and quick set up steps for the sFlow feature.
Detailed procedures are found in “sFlow” on page 35-29.
Note. sFlow is only supported on the OmniSwitch 6850 and OmniSwitch 9000 for this release.
sFlow Specifications
sFlow Defaults
The following table shows sFlow default values:
sFlow Defaults
RFCs Supported 3176 - sFlow
Management Information Base
Sampling Sampling rate of one (1) counts all packets and 0
(zero) disables sampling.
Agent IP Address As it need to send a fixed IP address in the data-
gram, loopback0 IP address is used.
Parameter Description CLI Command Default Value/Comments
Receiver Name sflow receiver Empty
Timeout Value sflow receiver 0 seconds
IP Address sflow receiver 32 bit address (IPv4)
Data File Size sflow receiver 1400 Bytes
Version Number sflow receiver 5
Destination Port sflow receiver 6343
Receiver Index sflow sampler 0
Packet Sampling Rate sflow sampler 0
Sampled Packet Size sflow sampler 128 Bytes
Receiver Index sflow poller 0
Interval Value sflow poller 0 seconds