UDLD Specifications Configuring UDLD
page 38-2 OmniSwitch 6800/6850/9000 Network Configuration Guide March 2008
UDLD Specifications
UDLD Defaults
RFCs supported Not applicable at this time
IEEE Standards supported Not applicable at this time
Probe-message advertisement timer 7 to 90 in seconds
Echo-based detection timer 4 to 15 in seconds
Maximum neighbors per UDLD port 32
Maximum number of UDLD ports per system 128
Parameter Description Command Default
UDLD administrative state udld Disabled
UDLD status of a port udld port Disabled
UDLD operational mode udld mode Normal
Probe-message advertisement timer udld probe-timer 15 seconds
Echo-based detection timer udld echo-wait-timer 8 seconds