Alcatel-Lucent OmniSwitch 6800 Series - Setting Ethernet Parameters for Non-Combo Ports; Setting Interface Line Speed

Alcatel-Lucent OmniSwitch 6800 Series
926 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting Ethernet Parameters for Non-Combo Ports Configuring Ethernet Ports
page 37-14 OmniSwitch 6800/6850/9000 Network Configuration Guide March 2008
Setting Ethernet Parameters for Non-Combo Ports
The following sections describe how to use CLI commands to configure non-combo ports. (See the tables
in “Valid Port Settings on OmniSwitch 6800 Series Switches” on page 37-5, Valid Port Settings on
OmniSwitch 6850 Series Switches” on page 37-5, and “Valid Port Settings on OmniSwitch 9000 Series
Switches” on page 37-6 for more information.)
Ports 1–20 on OmniSwitch 6800-24 and OmniSwitch 6850-24 switches are non-combo ports.
Ports 1–44 on OmniSwitch 6800-48 and OmniSwitch 6850-48 switches are non-combo ports.
While you can use the CLI commands described in the following sections to configure combo ports, please
keep in mind that configuration changes made on combo ports configured as either forced fiber or
preferred fiber will only be made on the SFP fiber connectors and not to the copper
RJ-45 10/100/1000 ports.
Similarly, configuration changes made on combo ports configured as either forced copper or preferred
copper, will only be made on the copper RJ-45 10/100/1000 ports and not to the SFP fiber connector. See
“Setting Combo Ethernet Port Parameters on OmniSwitch 6800 and 6850 Switches” on page 37-18 for
more information on configuring combo ports.
Setting Interface Line Speed
The interfaces speed command is used to set the line speed on a specific port, a range of ports, or all ports
on an entire switch (slot) to 10 (10 Mbps Ethernet), 100 (100 Mbps Ethernet), 1000 (1000 Mbps Gigabit
Ethernet), 10000 (10000 Mbps Gigabit Ethernet), or auto (auto-sensing, which is the default). The auto
setting automatically detects and matches the line speed of the attached device.
Note that available settings for the interfaces speed command depend on the available line speeds of your
hardware interface. See “Valid Port Settings on OmniSwitch 6800 Series Switches” on page 37-5, “Valid
Port Settings on OmniSwitch 6850 Series Switches” on page 37-5, or “Valid Port Settings on OmniSwitch
9000 Series Switches” on page 37-6 for more information.
In order to set up a speed and duplex on a port, autonegotiation should be disabled.
-> interfaces 2 autoneg disable
To set the line speed on an entire switch, enter interfaces followed by the slot number and the desired
speed. For example, to set slot 2 to 100 Mbps, enter:
-> interfaces 2 speed 100
To set the line speed on a single port, enter interfaces followed by the slot number, a slash (/), the port
number, and the desired speed. For example, to set the line speed on slot 2 port 3 at 100 Mbps, enter:
-> interfaces 2/3 speed 100
To set the line speed on a range of ports, enter interfaces followed by the slot number, a slash (/), the first
port number, a hyphen (-), the last port number, and the desired speed. For example, to set the line speed
on ports 1 through 3 on slot 2 at 100 Mbps, enter:
-> interfaces 2/1-3 speed 100