EasyManua.ls Logo

Alcatel-Lucent OmniSwitch 6800 Series - Setting Combo Ports to Preferred Copper; Setting Combo Ports to Forced Copper

Alcatel-Lucent OmniSwitch 6800 Series
926 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring Ethernet Ports Setting Combo Ethernet Port Parameters on OmniSwitch 6800 and 6850 Switches
OmniSwitch 6800/6850/9000 Network Configuration Guide March 2008 page 37-19
Setting Combo Ports to Preferred Copper
In preferred copper mode, combo ports will use the copper RJ-45 10/100/1000 port instead of the fiber
SFP connector, if both ports are enabled and have a valid link. If the copper port goes down, then the
switch will automatically switch to the fiber SFP connector. To set a single combo port, a range of combo
ports, or all combo ports on a switch to preferred copper use the interfaces hybrid preferred-copper
command.
To set all combo ports on an entire switch to preferred copper mode, enter interfaces, followed by the slot
number and hybrid preferred-copper. For example, to set all combo ports on slot 2 to preferred copper,
enter:
-> interfaces 2 hybrid preferred-copper
To set a single combo port to preferred copper, enter interfaces, followed by the slot number, a slash (/),
the port number, and hybrid preferred-copper. For example, to set port 47 on slot 1 to preferred copper,
enter:
-> interfaces 1/47 hybrid preferred-copper
To set a range of combo ports to preferred copper ports, enter interfaces, followed by the slot number, a
slash (/), the first port number, a hyphen (-), the last port number, and hybrid preferred-copper. For
example, to set combo ports 46 through 48 on slot 1 to preferred copper, enter:
-> interfaces 1/46-48 hybrid preferred-copper
As an option, you can document the interface type by entering ethernet, fastethernet, or gigaethernet
before the slot number. For example, to set port 47 on slot 1 to preferred copper and document the
interface type as Gigabit Ethernet, enter:
-> interfaces gigaethernet 1/47 hybrid preferred-copper
Setting Combo Ports to Forced Copper
In forced copper mode combo ports will always use the copper RJ-45 10/100/1000 port instead of the
equivalent fiber SFP connector. To set a single combo port, a range of combo ports, or all combo ports on
a switch to forced copper use the interfaces hybrid forced-copper command.
To set all combo ports on an entire switch to forced copper mode, enter interfaces, followed by the slot
number and hybrid forced-copper. For example, to set all combo ports on slot 2 to forced copper, enter:
-> interfaces 2 hybrid forced-copper
To set a single combo port to forced copper, enter interfaces, followed by the slot number, a slash (/), the
port number, and hybrid forced-copper. For example, to set port 47 on slot 1 to forced copper, enter:
-> interfaces 1/47 hybrid forced-copper
To set a range of combo ports to forced copper ports, enter interfaces, followed by the slot number, a
slash (/), the first port number, a hyphen (-), the last port number, and hybrid forced-copper. For exam-
ple, to set combo ports 46 through 48 on slot 1 to forced copper, enter:
-> interfaces 1/46-48 hybrid forced-copper
As an option, you can document the interface type by entering ethernet, fastethernet, or gigaethernet
before the slot number. For example, to set port 47 on slot 1 to forced copper and document the interface
type as Gigabit Ethernet, enter:
-> interfaces gigaethernet 1/47 hybrid forced-copper

Table of Contents

Other manuals for Alcatel-Lucent OmniSwitch 6800 Series

Related product manuals