Chapter 7
Seven Segment LED, Error Codes, cont’d
CODE
DESCRIPTION CODE
DESCRIPTION
H160 Reset instruction: push “RUN”. E155 Bad opcode at 0x______.
H162 Test module reset: push “RUN”. E156
Divide by zero at PC
0x______.
E001
Tie cycle aborted: ribbon not
threaded.
E157
Watchdog reset. Push
“RUN”.
E101
CPU detected a problem and stopped
Servo Tyer.
E158
Halt monitor reset. Push
“RUN”.
E102 Homing sequence failed. E162 CPU detected IRQ 1.
E111
Unable to control needle while
homing.
E163 CPU detected IRQ 2.
E112 Trailing edge of needle prox not found.
E164 CPU detected IRQ 3.
E113
Leading edge of needle prox not
found.
E165 CPU detected IRQ 4.
E114 Can't move needle to home position. E166 CPU detected IRQ 5.
E115 Needle motor not moving. E167 CPU detected IRQ 6.
E116 Needle jammed or encoder fault. E168 CPU detected IRQ 7.
E117 Needle home prox not detected. E169
Privileged instruction at
0x______.
E121 Unable to control hook while homing. E201
None of the three motors are
moving.
E122 Trailing edge of hook prox not found.
E300
Stack overflow error.