Troubleshooting 119
Flow Chart 0-4 Motor For Gathering Brushes Won't Run
Motor for gathering brushes won’t run
SAFETY WARNING:
The following troubleshooting procedure may require that tests be made with the electrical enclosures
open and power turned “ON”. These tests should only be conducted by authorized personnel who are
aware of the electrical and mechanical hazards present.
The gathering brushes use an AC induction motor, it is not a servo motor and it is not controlled by
the CPU. This test should be done with the gathering belts running. Start the tyer and turn the
brushes belts to “ON”. What is observed after turning brushes belts switch to “ON”?
Go to Flow Chart 4-3.
Go to Flow Chart 4-2.
Gathering belts won’t run.
The bagger active signal is
not getting from the bagger to
the tyer, Troubleshoot wiring
diagram.
Brushes begin running when switch
Is moved from “AUTO” to “ON”
Belts and brushes
not running
Belts are running
brushes are not