Troubleshooting 115
Audible Alarm Codes
A long beep is 1 second in duration. A short beep is 1/2 second in duration.
ALARM
CODE
DESCRIPTION
1 SHORT NONE
POWER TURNED ON, OR HOME SEQUENCE
SUCCESSFUL.
2 SHORT H006
BAG NECKS TOO CLOSE TOGETHER (TRIED TO
START 2ND CYCLE BEFORE 1ST CYCLE WAS
COMPLETED).
1 LONG H007
ABORTED TIE CYCLE, NOT ENOUGH RIBBON
USED.
2 LONG
E116, E126,
E136 or E146
ONE OR MORE MOTORS JAMMED OR ENCODER
FAULTS.
3 SHORT H008
HEEL TIED IN PACKAGE, TOO MUCH RIBBON
USED.
Troubleshooting Flow Charts
The troubleshooting flow charts on the following pages are intended to allow a serviceman
to repair a problem and get the Servo Tyer running again as quickly as possible.