HelixNet | User Guide
6.8.1 Viewing Powerline Information and Status
To view line information and status:
1. In Menu mode, select Diagnostics and then Powerlines.
2. From the third menu, select Powerline 1.
3. The fourth menu displays the status and other measures / information for the powerline. The
status of the powerline is either OK [operating normally], Busy or Error.
For more details of the information displayed, see Menu maps.
Note: Powerline status is also indicated by the powerline LEDS on the front panel.
Green LED = OK
Amber LED = Busy
Red LED = Error
For more information about powerline diagnostics, see Troubleshooting.
6.8.2 Viewing Network Information
To view network status information:
1. In Menu mode, select Diagnostics and then Network.
2. To view status information about the powerline:
a. From the third menu, select Powerline.
b. On the fourth menu, the IP address is given.
3. To view status information about the Ethernet:
a. From the third menu, select Ethernet.
b. On the fourth menu, the IP address is given.
6.8.3 Viewing Keyset Information
To view information about the keysets:
1. In Menu mode, select Diagnostics and then Keysets.
2. From the third menu, select a keyset from 1 to 4.
3. The fourth menu displays the following status information:
Page 115