2.4 GOODS INWARD INSPECTION ................................................................................................. 56
2.5 TOOLS ............................................................................................................................................. 56
2.6 EQUIPMENT GROUNDING ......................................................................................................... 56
2.7 V3 BDA/MU/RU MOUNTING BRACKET PREPARATION ...................................................... 57
2.8 V3 BDA/MU/RU WALL MOUNTING ............................................................................................ 58
2.9 V3 BDA/MU/RU SYSTEM WIRING - AC POWER ONLY (NO BBU) ..................................... 59
2.10 V3 BDA/MU/RU SYSTEM WIRING - DC POWER ONLY ........................................................ 61
2.11 V3 BBU WALL MOUNTING .......................................................................................................... 63
2.12 V3 BBU LIFEPO
4
BATTERY INSTALLATION AND WIRING .................................................. 64
2.13 V3 BDA/MU/RU AND BBU SYSTEM WIRING .......................................................................... 66
2.14 V3 BBU AC INPUT, EPO CONNECTION, AND CONVENIENT AC OUTLETS ................... 70
2.15 V3 BDA/MU/RU ADDITIONAL DC OUTPUTS .......................................................................... 73
2.16 V3 SYSTEM ALARM CONNECTION .......................................................................................... 75
2.17 V3 BDA/MU/RU ANNUNCIATOR FRONT PLATE INSTALLATION ...................................... 77
2.18 V2 FOU WALL MOUNTING.......................................................................................................... 79
2.19 V2 FOU 19IN RACK MOUNTING ................................................................................................ 80
2.20 V2 FOU POWER AND COMMUNICATIONS WIRING ............................................................. 81
2.21 V3 BDA/MU, V2 FOU, AND V3 RU RF AND FIBER WIRING ................................................. 83
2.22 V3 RU OPTICAL FIBER CABLE GLAND ASSEMBLY............................................................. 84
2.23 SYSTEM RF CONNECTIONS ..................................................................................................... 85
2.24 V1 AP ANNUNCIATOR PANEL INSTALLATION AND WIRING ............................................ 86
2.25 V3 AP ANNUNCIATOR PANEL INSTALLATION AND WIRING ............................................ 89
3 COMMISSIONING ....................................................................................................................... 102
3.1 PRE-COMMISSIONING TASKS ................................................................................................ 102
3.2 REQUIRED RF INPUTS FOR COMMISSIONING .................................................................. 103
3.3 COMMISSIONING PROCEDURE - BDA ................................................................................. 105
3.4 COMMISSIONING PROCEDURE – FIBER DAS OPTION 1 ................................................ 107
3.5 COMMISSIONING PROCEDURE – FIBER DAS OPTION 2 ................................................ 109
3.6 V3 BBU – WAKE UP/TURN ON THE BATTERY .................................................................... 111
3.7 V3 BBU – BATTERY SLEEP MODE/TURN OFF THE BATTERY ....................................... 112
3.8 V3 BBU – BATTERY ALARM RESET ....................................................................................... 113
3.9 V3 BDA/MU/FOU/RU POWER ON AND POWER OFF ......................................................... 113
3.10 WEB GUI LOGIN AND USER MANAGEMENT ....................................................................... 115
3.11 WEB GUI OVERVIEW (BDA MODE) ........................................................................................ 117
3.12 WEB GUI OVERVIEW (DAS MODE) ........................................................................................ 118
3.13 CHANGING THE DEVICE OPERATING MODE/TYPE (BDA OR DAS) ............................. 119
3.14 MODIFYING PARAMETERS VS PARAMETER DIRECT EDIT ........................................... 121
3.15 V3 FIBER DAS – SCANNING, VIEWING AND ACCESSING DEVICES ............................ 122
3.16 V3 BDA/MU/RU GENERAL SETTINGS ................................................................................... 127
3.17 CLASS A CARRIER MODE FILTER TEMPLATES ................................................................ 128
3.18 V3 BDA/MU NETWORK IP AND SNMP SETTINGS .............................................................. 129
3.19 ALARMS (DRY CONTACT / EXTERNAL ALARM / RF CONTROL) .................................... 130
3.20 BATTERY BACKUP UNIT .......................................................................................................... 133
3.21 EXTERNAL ANNUNCIATOR PANEL COMMISSIONING PROCEDURE ........................... 134
3.22 CREATE A NEW SITE AND ADD CHANNEL FILTERS (CLASS A ONLY) ....................... 137
3.23 CREATE SUB-BAND FILTERS (CLASS B ONLY) ................................................................. 141
3.24 COMMISSIONING TOOLS – DL INPUT TEST (CLASS A BDA ONLY) ............................. 142
3.25 COMMISSIONING TOOLS – UL INPUT TEST (CLASS A BDA ONLY) ............................. 144
3.26 COMMISSIONING TOOLS – ISOLATION CHECK ................................................................ 147
3.27 COMMISSIONING TOOL PARAMETER CALCULATIONS (CLASS A BDA) .................... 152
3.28 POWER, GAIN, ATTENUATION, AND AGC/ALC CONTROLS ........................................... 159
3.29 COMMISSIONING – SETTING POWER, GAIN, AND ATTENUATION .............................. 163
3.30 COMMISSIONING – PARAMETER OPTIMIZATION ............................................................. 168
3.31 COMMISSIONING FIBER DAS – PARAMETER SYNCHRONIZATION ............................. 173
3.32 ADVANCED SETTINGS – DL VSWR/RETURN LOSS MEASUREMENT .......................... 175