CRITICALPOINT 700/800MHZ BDA/DAS/BBU V3 USER MANUAL
©2024 Comba Telecom. All Rights Reserved.
568 Gibraltar Drive, Milpitas, CA 95035 | +1 408 526 0180
Rev. 1-0-2 Rev. Date: 11-1-2024
Page: 115
3.10 WEB GUI LOGIN AND USER MANAGEMENT
The V3 BDA/MU/RU and V2 FOU devices can be monitored and controlled via the WEB GUI; use the
following instructions to login to the GUI for system parameter setting and commissioning.
BDA/MU or RU Login
Set the computer IP address to 192.168.8.xxx (except 101) / 255.255.255.0. (e.g. 192.168.8.100)
Connect the computer to the OMT Port on the device using a regular Ethernet RJ45 Cable.
Use the default device IP address of http://192.168.8.101 in the browser to login to the device.
Enter full address with the <http://> all the time. Some browsers will default to use <https> and not be
able to access the device if just typing 192.168.8.101.
Use username admin and password admin for general web operation.
There is an additional LAN port located on the BDA/MU only. The LAN port can be used for local
access but more commonly used for remote access after being configured to connect to an external
Modem / Router / Switch or a Gateway, etc...
The LAN port IP can be configured in WEB > Management > Network.
The LAN port default IP address is 192.168.0.101 / 255.255.255.0, and the Gateway is 192.168.0.1.
Note: If the device is configured for remote connection using the LAN port, all the firmware
upgrades for the BDA/MU, FOU, and RUs can be completed remotely through the BDA/MU
without the need to send anyone to the site.
FOU Login
Set the computer IP address to 192.168.8.xxx (except 101) / 255.255.255.0. (e.g. 192.168.8.100)
Connect the computer to the OMT Port on the device using a regular Ethernet RJ45 Cable.
Use the default device IP address of https://192.168.8.101 (Must use https://) in the browser to
login to the device. Enter full address with the <https://> all the time for the FOU. If you receive any
security warnings from the web browser, they can be ignored.
First-time login: Use username admin and password admin for general web operation. If using an
older FW version, the system may prompt you to set a new password. Change the password and
notate accordingly.
Note: use admin/Admin12345678 if admin/admin does not work.