566 | Stacking
www.dell.com | support.dell.com
Figure 31-16. show redundancy Command Example
FTOS#show redundancy
-- Stack-unit Status --
--------------------------------------------------------
Mgmt ID: 0
Stack-unit ID: 0
Stack-unit Redundancy Role: Primary
Stack-unit State: Active Indicates Master Unit.
Stack-unit SW Version: E8-3-16-79
Link to Peer: Up
-- PEER Stack-unit Status --
--------------------------------------------------------
Stack-unit State: Standby Indicates Standby Unit
Peer stack-unit ID: 2
Stack-unit SW Version: E8-3-16-79
-- Stack-unit Redundancy Configuration --
---------------------------------------------------------
Primary Stack-unit: mgmt-id 0
Auto Data Sync: Full
Failover Type: Hot Failover Failover type with redundancy
force-failover
Auto reboot Stack-unit: Disabled
Auto failover limit: 3 times in 60 minutes
-- Stack-unit Failover Record --
------------------------------------------------
Failover Count: 0
Last failover timestamp: None
Last failover Reason: None
Last failover type: None
-- Last Data Block Sync Record: --
------------------------------------------------
Stack Unit Config: succeeded Mar 24 2012 20:07:39
Start-up Config: succeeded Mar 24 2012 20:07:39 Latest sync of config
Runtime Event Log: succeeded Mar 24 2012 20:07:39
Running Config: succeeded Mar 24 2012 20:07:39
ACL Mgr: succeeded Mar 24 2012 20:07:39
LACP: no block sync done
STP: no block sync done