EasyManuals Logo

Dell Force10 MXL Blade Configuration Guide

Dell Force10 MXL Blade
690 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #571 background imageLoading...
Page #571 background image
Stacking | 569
Master Switch Recovers from Failure
Problem: The master switch recovers from a failure after a reboot and rejoins the stack:
As a member unit if there is already a standby
As a standby if there is no standby in the stack
Protocol and control plane recovery requires time before the switch is fully online.
Resolution: When the entire stack is reloaded, the recovered master switch becomes the master unit of the
stack.
Stack Unit in Card-Problem State Due to Incorrect FTOS Version
Problem: A stack unit enters a Card-Problem state because the switch has a different FTOS version than
the master unit (Figure 31-19). The switch does not come online as a stack unit.
Resolution: To restore a stack unit with an incorrect FTOS version as a member unit, disconnect the
stacking cables on the switch and install the correct FTOS version. Then add the switch to the stack as
described in Adding a Stack Unit. To verify that the problem has been resolved and the stacked switch is
back online, use the
show system brief command (Figure 31-20).
Figure 31-19. Card Problem Error - Different FTOS Versions
FTOS#show system brief
Stack MAC : 00:1e:c9:f1:01:57
Reload Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
----------------------------------------------------------------------------------------------
---------------------------
0 Management online MXL-10/40GbE MXL-10/40GbE 8-3-16-79 56
1 Member card problem MXL-10/40GbE unknown 56
2 Standby online MXL-10/40GbE MXL-10/40GbE 8-3-16-79 56
3 Member not present
4 Member not present
5 Member not present

Table of Contents

Other manuals for Dell Force10 MXL Blade

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Force10 MXL Blade and is the answer not in the manual?

Dell Force10 MXL Blade Specifications

General IconGeneral
Switching Capacity1.28 Tbps
Forwarding Rate952 Mpps
Product TypeBlade Switch
Latency< 3 microseconds
Operating Temperature0°C to 40°C (32°F to 104°F)
RedundancyYes
ManagementCLI, SNMP, Web
Layer SupportLayer 2, Layer 3
Jumbo Frame SupportUp to 9216 bytes
Management Ports1 x 10/100/1000 Mbps
Storage Temperature-40°C to 70°C
Weight4.5 kg (9.9 lbs)

Related product manuals