Debugging and Diagnostics | 653
Figure 39-4.  show interfaces transceiver Command Example 
FTOS#show int ten 0/49 transceiver
SFP is present
SFP 49 Serial Base ID fields
SFP 49 Id                       = 0x03
SFP 49 Ext Id                   = 0x04
SFP 49 Connector                = 0x07
SFP 49 Transceiver Code         = 0x00 0x00 0x00 0x01 0x20 0x40 0x0c 0x01
SFP 49 Encoding                 = 0x01
SFP 49 BR Nominal               = 0x0c
SFP 49 Length(9um)    Km        = 0x00
SFP 49 Length(9um)    100m      = 0x00
SFP 49 Length(50um)   10m       = 0x37
SFP 49 Length(62.5um) 10m       = 0x1e
SFP 49 Length(Copper) 10m       = 0x00
SFP 49 Vendor Rev               =
SFP 49 Laser Wavelength         = 850 nm
SFP 49 CheckCodeBase            = 0x78
SFP 49 Serial Extended ID fields
SFP 49 Options                  = 0x00 0x12
SFP 49 BR max                   = 0
SFP 49 BR min                   = 0
SFP 49 Vendor SN                = P11C0B0
SFP 49 Datecode                 = 020919
SFP 49 CheckCodeExt             = 0xb6
SFP 49 Diagnostic Information
===================================
SFP 49 Rx Power measurement type        = Average
===================================
SFP 49 Temp High Alarm threshold        = 100.000C
SFP 49 Voltage High Alarm threshold     = 5.000V
SFP 49 Bias High Alarm threshold        = 100.000mA
SFP 49 TX Power High Alarm threshold    = 5.000mW
SFP 49 RX Power High Alarm threshold    = 5.000mW
SFP 49 Temp Low Alarm threshold         = -50.000C
SFP 49 Voltage Low Alarm threshold      = 0.000V
SFP 49 Bias Low Alarm threshold         = 0.000mA
SFP 49 TX Power Low Alarm threshold     = 0.000mW
SFP 49 RX Power Low Alarm threshold     = 0.000mW
===================================
SFP 49 Temp High Warning threshold      = 100.000C
SFP 49 Voltage High Warning threshold   = 5.000V
SFP 49 Bias High Warning threshold      = 100.000mA
SFP 49 TX Power High Warning threshold  = 5.000mW
SFP 49 RX Power High Warning threshold  = 5.000mW
SFP 49 Temp Low Warning threshold       = -50.000C
SFP 49 Voltage Low Warning threshold    = 0.000V
SFP 49 Bias Low Warning threshold       = 0.000mA
SFP 49 TX Power Low Warning threshold   = 0.000mW
SFP 49 RX Power Low Warning threshold   = 0.000mW
===================================
SFP 49 Temperature                      = 40.844C
SFP 49 Voltage                          = 3.169V
SFP 49 Tx Bias Current                  = 0.000mA
SFP 49 Tx Power                         = 0.000mW
SFP 49 Rx Power                         = 0.227mW
===================================
SFP 49 Data Ready state Bar             = False
SFP 49 Rx LOS state                     = False
SFP 49 Tx Fault state                   = False