EasyManua.ls Logo

Dell PowerConnect B-RX - Setting the Quiet Period; Setting the Interval for Retransmission of EAP-Request; Identity Frames; Specifying the Number of EAP-Request;Identity Frame

Dell PowerConnect B-RX
1458 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BigIron RX Series Configuration Guide 979
53-1002253-01
Configuring 802.1x port security
33
For example, to re-authenticate Clients connected to interface 3/1, enter the following command.
BigIron RX# dot1x re-authenticate e 3/1
Syntax: [no] dot1x re-authenticate <portnum>
Setting the quiet period
If the BigIron RX is unable to authenticate the Client, the BigIron RX waits a specified amount of
time before trying again. The amount of time the BigIron RX waits is specified with the quiet-period
parameter. This timer also indicates how long a client that failed authentication would have its
blocked entry programmed into the hardware.The quiet-period parameter can be from 0 –
4294967295 seconds. The default is 60 seconds.
For example, to set the quiet period to 30 seconds, enter the following command.
BigIron RX(config-dot1x)# timeout quiet-period 30
Syntax: [no] timeout quiet-period <seconds>
Setting the interval for retransmission of EAP-request/
identity frames
When the BigIron RX sends a Client an EAP-request/identity frame, it expects to receive an
EAP-response/identity frame from the Client. If the Client does not send back an
EAP-response/identity frame, the device waits a specified amount of time and then retransmits the
EAP-request/identity frame. You can specify the amount of time the BigIron RX waits before
retransmitting the EAP-request/identity frame to the Client. This amount of time is specified with
the tx-period parameter. The tx-period parameter can be from 1 – 65535 seconds. The default is
30 seconds.
For example, to cause the BigIron RX to wait 60 seconds before retransmitting an
EAP-request/identity frame to a Client, enter the following command.
BigIron RX(config-dot1x)# timeout tx-period 60
Syntax: [no] timeout tx-period <seconds>
If the Client does not send back an EAP-response/identity frame within 60 seconds, the device will
transmit another EAP-request/identity frame.
Specifying the number of EAP-request/identity frame retransmissions
If the BigIron RX does not receive a EAP-response/identity frame from a Client, the device waits 30
seconds (or the amount of time specified with the timeout tx-period command), then retransmits
the EAP-request/identity frame. By default, the BigIron RX retransmits the EAP-request/identity
frame a maximum of two times. If no EAP-response/identity frame is received from the Client after
two EAP-request/identity frame retransmissions, the device restarts the authentication process
with the Client.
You can optionally specify between 1 – 10 frame retransmissions. For example, to configure the
device to retransmit an EAP-request/identity frame to a Client a maximum of three times, enter the
following command.
BigIron RX(config-dot1x)# maxreq 3

Table of Contents