EasyManua.ls Logo

Dell PowerConnect B-RX - Disabling or Re-Enabling Syslog; Specifying a Syslog Server; Specifying an Additional Syslog Server

Dell PowerConnect B-RX
1458 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BigIron RX Series Configuration Guide 1295
53-1002253-01
Configuring the Syslog service
A
Disabling or re-enabling Syslog
Syslog is enabled by default. To disable it, enter the following command at the global CONFIG level.
BigIron RX(config)# no logging on
Syntax: [no] logging on [<udp-port>]
The <udp-port> parameter specifies the application port used for the Syslog facility. The default is
514.
To re-enable logging, enter the following command.
BigIron RX(config)# logging on
This command enables local Syslog logging with the following defaults:
Messages of all severity levels (Emergencies – Debugging) are logged.
Up to 50 messages are retained in the local Syslog buffer.
No Syslog server is specified.
Specifying a Syslog server
To specify a Syslog server, enter a command such as the following.
BigIron RX(config)# logging host 10.0.0.99
For backward compatibility, the software reads the old command syntax from the startup
configuration, and converts it to the new command syntax in the running configuration.
Syntax: logging host <ip-addr> | <server-name>
Specifying an additional Syslog server
To specify an additional Syslog server, enter the logging host <ip-addr> command again, as in the
following example. You can specify up to six Syslog servers.
Enter a command such as the following.
BigIron RX(config)# logging host 10.0.0.99
BigIron RX(config)# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 38 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
21d07h02m40s:warning:list 101 denied tcp 209.157.22.191(0)(Ethernet 4/18
0010.5a1f.77ed) -> 198.99.4.69(http), 1 event(s)
19d07h03m30s:warning:list 101 denied tcp 209.157.22.26(0)(Ethernet 4/18
0010.5a1f.77ed) -> 198.99.4.69(http), 1 event(s)
17d06h58m30s:warning:list 101 denied tcp 209.157.22.198(0)(Ethernet 4/18
0010.5a1f.77ed) -> 198.99.4.69(http), 1 event(s)