BigIron RX Series Configuration Guide 67
53-1002253-01
Restricting remote access to management functions
4
Restricting SSH access to a specific IP address
To allow SSH access to the device only to the host with IP address 209.157.22.39, enter the
following command.
BigIron RX(config)# ip ssh client 209.157.22.39
Syntax: [no] ip ssh client <ip-addr> | ipv6 <ipv6-addr>
Restricting Web Management access to a specific IP address
To allow Web Management access to the device only to the host with IP address 209.157.22.26,
enter the following command.
BigIron RX(config)# web client 209.157.22.26
Syntax: [no] web client <ip-addr> | ipv6 <ipv6-addr>
Restricting SNMP access to a specific IP address
To allow SNMP access (which includes IronView Network Manager or Brocade Network Advisor) to
the device only to the host with IP address 209.157.22.14, enter the following command.
BigIron RX(config)# snmp-client 209.157.22.14
Syntax: [no] snmp-client <ip-addr> | ipv6 <ipv6-addr>
Restricting all remote management access to a specific IP address
To allow Telnet, Web, and SNMP management access to the device only to the host with IP address
209.157.22.69, you can enter three separate commands (one for each access type) or you can
enter the following command.
BigIron RX(config)# all-client 209.157.22.69
Syntax: [no] all-client <ip-addr> | ipv6 <ipv6-addr>
Specifying the maximum number of login attempts for
Telnet access
If you are connecting to the device using Telnet, the device prompts you for a username and
password. By default, you have up to 3 chances to enter a correct username and password. If you
do not enter a correct username or password after 3 attempts, the device disconnects the Telnet
session.
You can specify the number of attempts a Telnet user has to enter a correct username and
password before the device disconnects the Telnet session. For example, to allow a Telnet user up
to 3 chances to enter a correct username and password, enter the following command:
BigIron RX(config)# telnet login-retries 5
Syntax: [no] telnet login-retries <number>
You can specify from 0 – 3 attempts. The default is 3 attempts.