Procedure
Set LRV and URV as desired.
Enter LRV and URV in the measurement units used for mA Output Source.
Defaults: Specific to each process variable
Range: Unlimited
Note
You can set URV below LRV. For example, you can set URV to 50 and LRV to 100. If you do this, an mA Output
will be inversely proportional to the value of mA Output Source.
8.4.3 Configure mA Output Direction
Display
MenuConfigurationInputs/OutputsChannel BI/O SettingsDirection
ProLink III Device ToolsConfigurationI/OOutputsmA OutputDirection
Field communicator Device SettingsInputs/OutputsmA Output xmAO x Direction
mA Output Direction controls how conditions of forward flow and reverse flow affect the flow rates reported
by an mA Output.
Actual flow direction interacts with Sensor Flow Direction Arrow to determine the flow direction that the
transmitter uses in processing. See the following table.
Table 8-1: Interaction between actual flow direction and Sensor Flow Direction Arrow
Actual flow direction
Setting of Sensor Flow Direction
Arrow
Flow direction sent to outputs and
totalizers
Forward (same direction as Flow arrow
on sensor)
With Arrow Forward
Against Arrow Reverse
Reverse (opposite from Flow arrow on
sensor)
With Arrow Reverse
Against Arrow Forward
Procedure
Set mA Output Direction as desired.
Option
Description
Normal (default) Appropriate when your application needs to distinguish between forward flow and reverse
flow.
Absolute Value Appropriate when your application does not need to distinguish between forward flow and
reverse flow.
Important
mA Output Direction interacts with Lower Range Value (LRV). The effect of mA Output Direction on an mA
Output varies, depending on whether LRV < 0 or LRV 0.
Related information
Configure Sensor Flow Direction Arrow
Integrate the meter with the control system Configuration and Use Manual
May2024 MS-00809-0200-1600