11.4.1 Start, stop, and reset totalizers using the display
Prerequisites
To stop, start, or reset a single totalizer or inventory, the totalizer or inventory must be configured as a display
variable.
To reset an inventory using the display, this function must be enabled. To enable inventory reset using the
display, choose MenuConfigurationSecurityDisplay SecurityTotalizers & Inventories Inventory
Reset and set Totalizer Reset to Allowed and save. Note that this affects only the display functions. Resetting
inventories using other tools is not affected.
Procedure
To start or stop a single totalizer or inventory:
a) Wait or scroll until the totalizer or inventory appears on the display.
b) Choose Options.
c) Choose Start or Stop.
To start or stop all totalizers and inventories as a group:
a) Choose MenuOperationsTotalizers.
b) Choose Start or Stop.
To reset a single totalizer or inventory:
a) Wait or scroll until the totalizer or inventory appears on the display.
b) Choose Options.
c) Choose Reset.
To reset all totalizers and inventories as a group:
a) Choose MenuOperationsTotalizers.
b) Choose Reset All.
11.4.2 Start, stop, and reset totalizers using ProLink III
Prerequisites
To reset an inventory using ProLink III, this function must be enabled. To enable inventory reset using ProLink
III, choose ToolsOptions and enable Reset Inventories from ProLink III. Note that this affects only ProLink
III. Resetting inventories using other tools is not affected.
Procedure
To start or stop a single totalizer:
a) Choose Device ToolsTotalizer ControlTotalizers.
b) Scroll to the totalizer that you want to start or stop, and click Start or Stop.
To start or stop a single inventory:
a) Choose Device ToolsTotalizer ControlInventories.
b) Scroll to the inventory that you want to start or stop, and click Start or Stop.
To start or stop all totalizers as a group:
a) Choose Device ToolsTotalizer ControlTotalizers or Device ToolsTotalizer Control
Inventories.
b) Select Start All Totals or Stop All Totals.
Transmitter operation Configuration and Use Manual
May2024 MS-00809-0200-1600
128 Emerson.com

Table of Contents

Other manuals for Emerson Micro Motion 1600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Micro Motion 1600 and is the answer not in the manual?

Emerson Micro Motion 1600 Specifications

General IconGeneral
BrandEmerson
ModelMicro Motion 1600
CategoryTransmitter
LanguageEnglish

Related product manuals