154 Eos Family Operations Manual
To change the setting for any of these fields, press the field in the CIA to activate it. If the field
requires data, enter it from the keypad. If the field is a toggle state, one press of the button will
switch the field to its other state.
{Auto-Mark}
This toggles the AutoMark settings between enabled/ disabled (see AutoMark(on page216) for
more information). AutoMark is “Disabled by default.
{Mark Time}
This field allows you to set the time that mark instructions will use. When {Mark Time} is disabled,
which is the default, mark instructions will use cue timing unless overridden with discrete timing.
When you enter a mark time in setup, all NPs that mark (either through referenced marking or
AutoMark) will use this time. The only way to override setup mark time is to use discrete timing.
Clearing the {Mark Time} field sets it back to disabled. Select {MarkTime} and hit [Enter] to disable the
default mark time.
{Preheat Time}
If this option is disabled, the cue’s up intensity time will be used when preheating. The default setting
is “Disabled”.
Cue Default Times
This area allows you to set the default cue times for the parameter categories of your system. To
change a time, touch the parameter category button in the CIA and enter the desired time on the
keypad. To set a time for all categories at once, press {Selection Button} [Thru]. Pressing [At] selects
manual times.
The categories for which you may set default times are:
Intensity Up
Intensity Down
Color
Focus
Beam
Show Control Setup
This section allows you to adjust settings for MIDI show control, time code (MIDI or SMPTE), analog,
and serial functions. For more information on using show control with your system, see About Eos
FamilyShow Control(on page494)
Smpte
{SMPTE Time Code Rx}
This button is used to control whether your console can receive SMPTE time code. Choosing “Dis-
abled” will disable all time code lists that have a SMPTE source. The default for this setting is
“Enabled”.

Table of Contents

Other manuals for ETC Element 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ETC Element 2 and is the answer not in the manual?

ETC Element 2 Specifications

General IconGeneral
DMX Outputs2
TouchscreenYes
NetworkingEthernet
TypeLighting Control Console
Master Faders2
Encoders4
Ethernet Ports2
USB Ports4
Video OutputDisplayPort
Power Input100-240VAC, 50/60Hz
Power SupplyInternal
Control Channels6144
OutputArt-Net
DisplayMulti-Touch LCD
StorageSolid State Drive (SSD)